@alsancle stanley has a pressure diaphram that deforms with pressure and closes a valve in the fuel line . With the stanley this device turns the fire of at a set pressure that is lower than the second safety device which is a saftey valve venting to the atmosphere .
Doble control is all electrical . The pumps are actuated by solenoids and the burner is fan driven. All turning on and off based on demand